Scb11-160/10 dry type transformer has the advantage of fire protection and no pollution, and can run directly in the load center. The SCB11-160/10 dry-type transformer produced by our factory adopts German HTT technology, featuring high mechanical strength, strong short-circuit resistance, small partial discharge, good thermal stability, high reliability, long service life, strong overload capacity, and improved capacity operation when forced air cooling.
Scb11-160/10 Dry type transformer Structure features:
1. The core material is made of high-quality cold-rolled oriented silicon steel sheet with full inclined joints and laminated structure
2. The low-voltage coil is of foil-type winding structure, which is made of high-quality steel foil. The high-voltage coil is of layer structure and formed by vacuum epoxy casting
Scb11-160/10 Dry type transformer application range: SCB9 series resin insulated dry type transformer has many advantages, such as strong thermal shock resistance, large overload capacity, difficult to burn, high fire resistance, insensitive to humidity and dust, etc., which makes it widely adaptable. SCB9 series resin insulated dry transformers are most suitable for use in harsh environments with high fire requirements, large load fluctuations and pollution and humidity. Such as: airports, subways, power plants, metallurgy, hospitals, high-rise buildings, shopping centers, densely populated areas, petrochemical, nuclear power, nuclear submarines and other important places. It is the most ideal power supply and distribution equipment.
Scb11-160/10 Dry type transformer Structure features:
1. The core material is made of high-quality cold-rolled oriented silicon steel sheet with full inclined joints and laminated structure.
2. The low-voltage coil is of foil-type winding structure, which is made of high-quality steel foil. The high-voltage coil is of layer structure and formed by vacuum epoxy casting.
SCB10 series transformers:
The following conditions shall be considered as normal conditions:
A. The altitude is not more than 1000m.
B. Maximum ambient temperature +40℃ maximum daily average temperature +30℃ Maximum annual average temperature +20℃ minimum temperature -30℃(for outdoor type transformer, minimum temperature -5℃ (for indoor type transformer)
The waveform of the supply voltage is similar to a sine wave.