How to measure insulation of dry type transformer

Release time:2021-04-19 10:43:44 Popularity: Source:未知

    Dry type transformer can work without transformer oil. There are many performances of dry-type transformer. Generally, the insulation performance of dry-type transformer is an important feature of dry-type transformer, and its insulation performance varies greatly. Its size can be measured. How to measure the insulation performance of dry-type transformer? Let's have a detailed look with the editor of transformer manufacturer

     When the solid insulating material is broken down, it will irreversibly lose its electrical insulation performance. Therefore, the insulation selection of electrical lines and equipment must match the voltage level, and must adapt to the use environment and operating conditions, so as to ensure the safety of insulation. In addition, due to corrosive gas, vapor, moisture, conductive dust and mechanical operation, the insulation performance of insulating materials may be reduced or even damaged. Moreover, the long-term effect of environmental factors, such as sunlight, wind and rain, can also make the insulation material aging and gradually lose its insulation performance. The insulation resistance of various lines and equipment under different conditions is as follows: in general, the low voltage after new installation or overhaul shall not be less than 100m Ω; the insulation resistance of low voltage lines and equipment in operation shall not be less than 3m Ω / V; the insulation resistance of equipment and lines in wet conditions shall not be less than 2.5m Ω / V; the insulation resistance of equipment and equipment in operation shall not be less than 3m Ω / V; the insulation resistance of equipment and equipment in wet conditions shall not be less than 2.5m Ω / v; The insulation resistance of control line shall not be less than 1m Ω, and that of high voltage line and equipment shall not be less than 1000m Ω.

The above are the main measurement standards and common measurement methods of the insulation performance of the common dry-type transformer for your reference. If you have any other opinions and questions about the insulation performance of the dry-type transformer, please visit our website for detailed understanding!
High voltage ring main unit
KBSG mine flameproof dry type transformer
KSG mine general dry type transformer

Online Message

invisibility? Click changeinvisibility?
Service
Contact

Hotline

+86-185-5293-9138

work shift

from Monday to Friday

Company phone

+86-185-5293-9138

QR code
Service