Dry-type transformer is an important electrical appliances, it is also to pay attention to a variety of operations in the process of operation, which is more common dry-type transformer. The main treatment of dry-type transformers is to prevent short-circuit of dry-type transformers from drying out because the dry-type transformers are sometimes wet or wet when they are working. Common dry-type transformer there is no need to dry depends on the following cases:
(1) a comprehensive analysis of the following conditions shall be made as to whether the newly installed dry-type transformer with oil transportation needs to be dried, by * * * , It is confirmed that: 1) the electrical strength of the insulating oil and the trace water test are qualified; 2) the insulation resistance and the absorption ratio (or the polarization index) conform to the relevant provisions of the current national standard "electrical equipment handover test standard for electrical installation engineering" (GB 50150-2006) . 3) dielectric loss angle tangent value Tan (%) conforms to the regulation (voltage class below 35kV and capacity at 4000kv V. Below A, not required). (2) for newly installed dry-type transformers and reactors for air-filled transportation, the following conditions should be comprehensively analyzed to determine whether they need to be dried: 1) the pressure inside the body of the device shall be kept positive from the time of leaving the factory to the time of installation; 2) the trace water in the residual oil shall not be greater than 30 PPM; 3) after the qualified insulating oil is injected into the dry-type transformers and reactors, the trace water of the electrical strength of the insulating oil and the insulating resistance shall conform to the relevant provisions of the current national standard "electrical installation project, electrical equipment handover test standard" (GB 50150-2006) . (3) when the positive pressure is not maintained and the seal is not obviously damaged, a comprehensive analysis of the installation and test records should be made to determine whether drying is required. Dry-type transformer is not to be dry, to see if there is a need to dry, dry-type transformer to improve its drying process, so that dry-type transformer can operate safely and smoothly, to achieve continuous improvement in efficiency. For more information about dry-type transformers please contact our technical staff!
Hotline
+86-185-5293-9138
work shift
from Monday to Friday
Company phone
+86-185-5293-9138